Independent Testing & Compliance

Test Results & Certifications

Each result below names the laboratory that ran the test, the standard it was run to, the size of the chamber, how long it ran, and which model was tested. Where a certificate applies, the certificate number is there so you can verify it in the issuing body’s own database rather than taking our word for it.

We don’t publish figures we can’t stand behind. That makes this page shorter than some you’ll see.

Certification

The PurAire SG- BPI-2, also sold as the SG-FCU-2, holds a UL Environmental Claim Validation for zero ozone emissions.

Certificate 344035-4710, issued by UL Verification Services Inc.

Product: Bipolar Ionizer PS-502T (PurAire BPI-2 / FCU-2)

Claim validated: measured ozone emissions during the use phase do not exceed 0.005 ppm, as tested by UL 867

Method: ECVP 2998, Zero Ozone Emissions from Air Cleaners, Third Edition 2020

You can check this certificate is current at SPOT.ul.com.

What this covers: The validation applies to the BPI-2 / FCU-2 (model PS-502T). It does not cover the BPI-1, the PurAire DUO or the AirPro-MAX. Those models are not covered by this certificate and we don’t claim they are.

Independent Test Results

These tests were run on the PurAire SG-BPI-1, (model PS-501T). The SG-BPI-1 is the single-tube version of the same unit as the SG-BPI-2. Both were tested by accredited laboratories in China on samples submitted by the manufacturer that builds our units.

Airborne Bacteria

Six organisms, tested separately, three runs each.

  • Klebsiella pneumoniae — 99.99%, 99.97%, 99.98%
  • Pseudomonas aeruginosa — 99.98%, 99.99%, 99.99%
  • Salmonella typhimurium — 99.98%, 99.97%, 99.98%
  • Acinetobacter baumannii — 99.98%, 99.98%, 99.98%
  • Mycobacterium chelonei subsp. abscesses — 99.97%, 99.98%, 99.97%
  • Bacillus subtilis spores — 99.08%, 99.05%, 99.09%

20 m³ chamber. 120 minutes. Technical Standard for Disinfection (2002), section 2.1.3.

CAS Testing Technical Services (Guangzhou) Co., Ltd — reports JKK24030021A(E), C(E), D(E), F(E), G(E) and H(E). CMA 201819000873, CNAS L7673.

About That Last Figure....

The standard sets 99.90% as its threshold. Bacillus subtilis spores came in below it, at 99.05 to 99.09%.

Spores are built to survive. They are harder to reduce than ordinary bacteria, which is exactly why they get tested — they show you where the limit is. Five of the six organisms cleared the threshold comfortably. The sixth did not, and we publish it because leaving it out would misrepresent what the panel actually found.

Gaseous Pollutants

Hydrogen sulfide 90.6%. Benzene 94.0%. TVOC 95.5%.

30 m³ chamber. 4 hours. JG/T 294-2010.

Guangdong Detection Center of Microbiology — report 2024FM00355R01E, verification code 6BDNV4J6. CMA 201819000883, CNAS L1747.

One note on this test: JG/T 294-2010 works out the test duration from the unit’s rated airflow, which for this model comes to five hours. The test ran for four. The laboratory recorded the difference and confirmed the result holds for the conditions tested.

What These Results Don't Tell You

Every figure above was measured on one model, in a sealed chamber, under laboratory conditions. A real room is not a chamber. Ceiling height, air movement, how often the door opens and what’s producing the odour or contamination in the first place all change what you’ll see in practice.

Test results describe the sample tested. They are not a performance guarantee for your building.

We Don't Audit Our Own Work

When a building or a site needs measuring, we engage TÜV SÜD Singapore. They are SAC-SINGLAS accredited for formaldehyde, TVOC, PM2.5 and respirable suspended particles.

They conduct the audit. They write the report. It carries their name, not ours.

Where a client would rather engage and pay them directly, that works too.

The measurement and the fix are done by different people. An accredited laboratory measures. We correct what the measurement found. The laboratory verifies.

About The Reports

PurAire units are built to our specification by our manufacturing partner in Shenzhen. They commissioned the tests above and have authorised us to cite them. The reports carry the manufacturer’s own brand and model numbers, which is why PS-501T and PS-502T appear on this page alongside the PurAire names.

Measured at Room Scale Under Stated Conditions

Every figure below comes from an accredited third-party laboratory, tested in a sealed chamber over a stated duration.

TEST 01 — MICROBIAL
99.97%–99.99%

Reduction across six pathogens. Bacillus subtilis spores reached 99.05-99.09% – below the others, and we publish it that way. 

TEST 02 — VOC & ODOUR
95.0–97.6%

TVOC 97.6% · Benzene 97.0% · Hydrogen sulphide 96.6% · Ammonia 95.6% · Formaldehyde 95.0%.

TEST 03 — PM2.5
99.94%

Particulate removal, against 4.55% for natural settling over the same period in the same chamber.

About These Test Results Published Below:

Independent Laboratory Test Results Supplied by Our Manufacturer

The test results shown below are taken from independent laboratory reports supplied to PurAire by our equipment manufacturer. PurAire Singapore and ProMedUSA did not conduct these tests. The results are reproduced from the supporting test documentation provided by the manufacturer.

Reduction in GX-P2V

99.99%

Action in 1 Min

Source: WP-21029109-JC-01EnR1

Reduction in ASFV

99.99%

Action in 1 Min

Source: WP-21029109-JC-01En

Reduction in HCoV-229E

99.99%

Action in 30 Min

Source: WP-21019007-JC-01En

Reduction in H1N1 & EV71

99.9%

Action in 2 Hours

Source: GT-2020FM02909R01E

Reduction in Escherichia coli

99.6%

Action in 55 Min

Source: TUV-721668492

Reduction in Staphylococcus aureus

99.4%

Action in 55 Min

Source: TUV-721668492

Reduction in Aspergillus niger

99.99%

Action in 24 Hours

Source: GT-2019SP0928R01E

Reduction in Staphylococcus albus

99.96%

Action in 1 Hours

Source: CGMT-KJ20204593

Reduction in Air natural bacteria

92.3%

Action in 1 Hours

Source: CGMT-KJ20204593

Reduction in TVOC 30m² Test Chamber

91.1%

Action in 24 Hours

Source: GT-2019SPC928R02E

Reduction in Benzene 30m² Test Chamber

81.8%

Action in 24 Hours

Source: GT-2019SP0928R02E

Reduction in Formaldehyde 30m² Test Chamber

82.4%

Action in 24 Hours

Source: GT-2019SP0928R02E

Reduction in Hydrogen Sulfide 30m² Test Chamber

85.2%

Action in 24 Hours

Source: GT-2019SP0928R02E

Reduction in Ammonia 30m² Test Chamber

89.6%

Action in 24 Hours

Source: GT-2019SP0928R02E

Reduction in PM2.5 30m² Test Chamber

99.71%

Action in 1 Hours

Source: CGMT-QX20210332

Key Certificate & Report Index

Searchable reference numbers featured within the testing matrix:

Ready to Upgrade
Your Commercial Space’s
Air Quality? Tell us your IAQ or Odour Problem.

Describe the space and problem you’re trying to solve. We’ll recommend the most appropriate Puraire solution.

Contact our Singapore IAQ experts today for a tailored quote, site evaluation, or a free on-site live product demo.

— Tel
+65 6836 9665
— WhatsApp
+65 9456 8313
— Email
— Singapore Office
PurAire Singapore
(Division of ProMedUSA Pte Ltd),
111 North Bridge Road,
#08-27, Peninsula Plaza
Singapore 179098